Zero resistance ammetry is the measure of galvanic currents between two materials. This is accomplished by placing samples of the materials into a sensor unit, which is placed in the system environment. Deviation from actual component materials may occur due to slight differences in composition, heat treatment, surface condition and applied stresses. This technique can be used to monitor changes to the environment by using the same material for both sensor elements.